| Technical data - electrical ratings | |
|---|---|
| Voltage supply | 10...30 VDC |
| Reverse polarity protection | Yes |
| Consumption w/o load | ≤200 mA (24 VDC) |
| Initializing time | ≤2000 ms after power on |
| Interface |
CANopen® Analog (4...20 mA or 0...10 V) |
| Frequency bands | 6 (configurable) |
| Measuring range | ±2 g |
| Resolution | <4 mg |
| Accuracy 3σ (with band pass filtering) |
=35 mg (in the range of ±1000 mg) =10 mg (in the range of ±250 mg) |
| Interference immunity |
DIN EN 61000-6-2 EN 61326-3-1 |
| Emitted interference | DIN EN 61000-6-4 |
| Status indicator | DUO-LED integrated in housing |
| Approval |
UL approval / E63076 Option: PLd according to EN ISO 13849-1:2008 +AC:2009 SIL CL2 according to EN 62061:2005 +AC:2010 +A1:2013 SIL2 according to IEC 61508-1..7:2010 |
| Technical data - mechanical design | |
| Dimensions W x H x L | 55 x 30 x 90 mm |
| Protection DIN EN 60529 | IP 67 |
| Material |
GAM900-M: Aluminium GAM900-P: glass-fiber reinforced plastic |
| Operating temperature | -40...+85 °C |
| Resistance |
DIN EN 60068-2-6 Vibration 20 g, 60-2000 Hz DIN EN 60068-2-27 Shock 100 g, 6 ms |
| Weight approx. |
200 g (plastic) 250 g (Aluminium) |
| Connection | Connector M12, 12-pin |

| Technical data - electrical ratings | |
|---|---|
| Voltage supply | 10...30 VDC |
| Reverse polarity protection | Yes |
| Consumption w/o load | ≤200 mA (24 VDC) |
| Initializing time | ≤2000 ms after power on |
| Interface |
CANopen® Analog (4...20 mA or 0...10 V) |
| Frequency bands | 6 (configurable) |
| Measuring range | ±2 g |
| Resolution | <4 mg |
| Accuracy 3σ (with band pass filtering) |
=35 mg (in the range of ±1000 mg) =10 mg (in the range of ±250 mg) |
| Interference immunity |
DIN EN 61000-6-2 EN 61326-3-1 |
| Emitted interference | DIN EN 61000-6-4 |
| Status indicator | DUO-LED integrated in housing |
| Approval |
UL approval / E63076 Option: PLd according to EN ISO 13849-1:2008 +AC:2009 SIL CL2 according to EN 62061:2005 +AC:2010 +A1:2013 SIL2 according to IEC 61508-1..7:2010 |
| Technical data - mechanical design | |
| Dimensions W x H x L | 55 x 30 x 90 mm |
| Protection DIN EN 60529 | IP 67 |
| Material |
GAM900-M: Aluminium GAM900-P: glass-fiber reinforced plastic |
| Operating temperature | -40...+85 °C |
| Resistance |
DIN EN 60068-2-6 Vibration 20 g, 60-2000 Hz DIN EN 60068-2-27 Shock 100 g, 6 ms |
| Weight approx. |
200 g (plastic) 250 g (Aluminium) |
| Connection | Connector M12, 12-pin |